Microbiological Safety Cabinet CLASS ΙΙ / A2 - 1065x900x2250 mm

MLF Series Class II Biological Safety Cabinets

Providing top-level protection for the user, environment, and product, MLF Series Biological Safety Cabinets are designed for all studies involving harmful microorganisms and microorganisms with an undetermined level of hazard.

MLF Class II Biological Safety Cabinets provide first-class protection for the operator, environment, and the samples being worked on against aerosols emitted from potentially hazardous or hazardous microorganisms within the cabinet.

The outer body of the cabinets is made of electrostatic powder-coated sheet steel. The worktable is made of stainless steel to resist contamination for easy cleaning. The laminated tempered front window does not transmit UV rays.

Control Panel Features

The control panel is digital and has an LCD display. The control panel includes the following parameters:

  • Airflow velocity
  • Total operating time
  • Time counter
  • HEPA filter lifespan
  • Front glass
  • UV lamp
  • Total operating time/lifespan of the UV lamp
  • UV lamp countdown timer
  • Airflow velocity of the particulate-free air supplied to the work area

The device has 2 HEPA type filters that retain particles larger than 0.3 microns. The minimum efficiency level is 99.999%. (According to DOP test) The decontamination factor (F) is a minimum of 100,000.

The air ducts in the device that pose a contamination risk are kept under negative pressure, thus preventing particle mixing into the air entering the work area.

Design and Usage Advantages

  • MLF Class II Biological Safety Cabinets are designed considering only safety, ease of use, user comfort, and ease of maintenance.
  • O.P. test port is offered as standard.
  • HEPA filters can be replaced easily and in a short time. The easily accessible control system is placed outside the contaminated area.
  • No effort or time is required to clean the inside of the glass window. The automatic window opens fully and stays fixed, providing ease of cleaning.
  • Since all operations are performed automatically, the user does not need to make any adjustments.
  • The noise level is very low thanks to the silent fan.

Technical Specifications

MLF Series Class II Biological Safety Cabinets - Technical Specifications
HEPA FilterIt is a HEPA type filter that retains particles larger than 0.3 microns. The minimum efficiency level is 99.999%. (According to D.O.P test) The decontamination factor (F) is a minimum of 100,000.
Work Cabinet2mm cold-rolled steel DKP with epoxy electrostatic powder coating, lower cabinet is removable on wheels or a fixed system with a metal cover, gas and water outlet nozzles with hose ends inside the cabinet, heavy and light gas adjustment panel, fluorescent lighting inside the cabinet, UV lighting, hood section with a system suitable for airflow physics.
Work SurfaceRemovable perforated AISI 304 stainless steel, anti-acid compact laminate.
Pre-filterIt is a synthetic fiber-based filter. It filters particles in the air coming to the HEPA filter, extending the lifespan of the HEPA filter.
FanStandard EN 60034-1 Protection class IP44 Steel body, single suction centrifugal type blower. Fan and motor are statically balanced. Laminar air velocity is 0.35-0.55 m/s.
LightingLow power high intensity 800 Lux (Fluorescent Lamp/UV Lamp).
Working DimensionsOptional
PaintAfter metal parts are cleaned with special solvents, they are coated with electrostatic epoxy powder paint and baked at 200°C.
Noise Level55 dBA
Standard AccessoryPedestal support stand, UV lamp, speed adjustable dimmer switch, filter life counter.
OptionsComplete inner chamber stainless steel, gas and water valve, sink, cabinet.
Installed Power220 Volt/50Hz
Airflow ControlManual Speed Control
Other Technical SpecificationsThe device is manufactured in accordance with user requests and laboratory conditions.