Microbiological Safety Cabinet CLASS ΙΙ / B2 - 1965x900x2250 mm
Product Code: MGK-180/B2
MLF Series Class II Biological Safety Cabinets
Designed for all studies involving harmful microorganisms and microorganisms with an undetermined hazard level, the MLF Series Biological Safety Cabinets offer top-level protection for the user, the environment, and the product.
MLF Class II Biological Safety Cabinets provide first-class protection for the operator, the environment, and the samples being worked on against aerosols emitted from potentially hazardous or hazardous microorganisms within the cabinet.
The outer body of the cabinets is made of electrostatic powder-coated sheet steel. For easy cleaning, the work surface is made of stainless steel to prevent contamination. The laminated tempered front window does not transmit UV rays.
The control panel is digital and has LCD indicators. The following parameters are located on the control panel:
- Airflow velocity
- Total operating time
- Time counter
- HEPA filter lifespan
- Front glass
- UV lamp
- Total operating time/lifespan of the UV lamp
- UV lamp countdown timer
- Airflow velocity of the particulate-free air supplied to the work area
The device has 2 HEPA type filters that retain particles larger than 0.3 microns. The minimum efficiency level is 99.999%. (According to DOP test) The decontamination factor (F) is a minimum of 100,000.
The air ducts in the device that pose a contamination risk are kept under negative pressure, thus preventing particle mixing into the air entering the work area.
- MLF Class II Biological Safety Cabinets are designed solely with safety, ease of use, user comfort, and ease of maintenance in mind.
- O.P. test port is offered as standard.
- HEPA filters can be replaced easily and in a short time. The easily accessible control system is placed outside the contaminated area.
- No effort or time is required to clean the inside of the glass window. The automatic window opens fully and remains fixed, providing ease of cleaning.
- Since all operations are performed automatically, the user does not need to make any adjustments.
- The noise level is very low thanks to the silent fan.
Technical Specifications
| MLF Series Class II Biological Safety Cabinets - Technical Specifications | |
| HEPA Filter | It is a HEPA type filter that retains particles larger than 0.3 microns. The minimum efficiency level is 99.999%. (According to DOP test) The decontamination factor (F) is a minimum of 100,000. |
| Work Cabinet | 2mm cold-rolled steel DKP with epoxy electrostatic powder coating, lower cabinet is removable from its place or a fixed system with a metal cover, gas and water outlet nozzles with hose ends inside the cabinet, heavy and light gas adjustment panel, fluorescent lighting inside the cabinet, UV lighting, and a hood section with a system suitable for airflow physics. |
| Work Surface | Demountable perforated AISI 304 stainless steel, anti-acid compact laminate. |
| Pre-filter | It is a synthetic fiber-based filter. It filters the particles in the air coming to the HEPA filter, extending the lifespan of the HEPA filter. |
| Fan | Standard EN 60034-1 Protection class IP44 Steel body, single suction centrifugal type blower. Fan and motor are statically balanced. Laminar air velocity is 0.35-0.55 m/s. |
| Lighting | Low power high intensity 800 Lux (Fluorescent Lamp / UV Lamp). |
| Working Dimensions | Optional |
| Paint | After metal parts are cleaned with special solvents, they are coated with electrostatic epoxy powder paint and baked at 200°C. |
| Noise Level | 55 dBA |
| Standard Accessory | Pedestal support stand / UV lamp / Speed adjustable dimmer switch / Filter life counter. |
| Options | Complete inner chamber stainless steel / Gas and water valve / Sink / Cabinet. |
| Installed Power | 220 Volt / 50Hz |
| Airflow Control | Manual Speed Control |
| Other Technical Specifications | The device is manufactured in accordance with user requests and laboratory conditions. |