Determination of Thermal Shock Resistance of Aggregates
Product Code: Determination_Resistance_Thermal_Shock
Categories:
EN 1367-5
This test involves heating wet aggregates to 700°C for 3 minutes and comparing the fine dust and strength loss determined according to EN 1097-2, using appropriate accessories, before and after heating.
Ash Furnace - Touch Screen
| Feature | Value |
|---|---|
| Model | MKF-5 |
| Continuous Operating Temperature (°C) | 1100 |
| Internal Volume (Lt.) | 5 |
| Inner Chamber | High temperature resistant ceramic insulation |
| Control Unit | Programmable PID Microprocessor Control Unit |
| Program and Step-1 | 5 Programs - 5 Steps |
| Program and Step-2 | 10 Programs - 10 Steps |
| Power Supply (V-Hz) | 220V-50Hz |
| Power (Watt) | 2000W |
| Inner Chamber Dimensions (WxDxH)(cm) | 15x23x15 |
| External Dimensions (WxDxH)(cm) | 44x49x55 |
Accessories
| Code | Description |
|---|---|
| MKF-5-01 | Metal test plate, 440 x 240 x 4 mm thickness, with 12 mm high lips. |
| MKF-5-02 | Metal support frame for metal test plate. |
| MKF-5-03 | Heat-resistant plate 450 x 250 x 10 mm thickness. |
| MKF-5-04 | Stainless steel sieve, 2 mm mesh, 250 x 445 mm dimensions. |