Xenon Arc Aging Test Chamber
Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber Xenon Arc Aging Test Chamber

Application

Suitable for wear tests on various materials such as automotive materials, building materials, packaging materials, coatings, fabrics, rubber, pigments, and adhesives.

Also used for quality control and research in metrology, universities, scientific research laboratories, and technical inspection departments.

Standards

  • ISO 11507, ISO 4892-2
  • ASTM G155, ASTM D2565, ASTMD4459
  • IEC60068-2-5
  • SAE J2527, SAE 242

Features

  • Ventilation system: Automatically controlled by a temperature controller and cooled by an inner chamber cooling system
  • Rear panel thermometer: Adopts wired transmission technology, which greatly improves control accuracy.
  • Temperature sensor: PT100 platinum resistance thermocouple.
  • Smart temperature and humidity controller: Has PID setting and fast automatic return feature. Various parameters can be adjusted for cyclic testing, and a direct digital temperature display is available for easy reading.
  • Multiple protection controls: Over-temperature protection, water leakage alarm, compressor over-pressure, electric leakage protection, alarm and automatic power protection. To protect the Xenon light, it automatically turns off when the door is opened.

Technical Specifications

Technical SpecificationsE711-1
Internal Dimensions (W*D*H)500*500*600mm
External Dimensions (W*D*H)1050×1080×1750mm
Inner chamber materialSUS 304 # Stainless Steel, rust-proof
Outer chamber materialSprayed cold rolled steel
Chamber humidity range50% ~ 98% adjustable
Humidity deviation± %2.5 R.H (humidity ≥%75 R.H)
± %3 relative humidity (humidity ≤%75 relative humidity) (without light)
Chamber temperature35~90°, adjustable
Temperature deviation± 2° (without light)
Black panel temperature45~95°, adjustable
FilterWindow glass filter / Daylight filter / Extended UV filter, any one optionally
Light sourcewind-cool full sun spectrum long arc lamp
(average service life approximately 1600 hours)
Spectral wavelength300nm ̴̴ 800nm
Xenon lamp power3.6 kW (2 lamp tubes) (life: 1600 hours)
Light source irradiance0.51 W/m2@340 nm (ISO 4892-2 method A cycle No 1)
LCD programmable controller,
Control systemAutomatic display light intensity, capacity: 100 group programs, 99 cycles.
Spray duration1 to 9999 minutes, adjustable
Spray cycle1 to 240 minutes, interval (cut-off) adjustable
Water spray systemSpray time: 0-99 hours 59 minutes, continuously adjustable
Spray stop time: 0-99 hours 59 minutes, continuously adjustable.
Sample holderStainless steel, 1 piece
Distance from sample holder to lamp350~380 mm
Sample rotation basket speed≥1r/min