Salt Spray Corrosion Test Cabinet
Product Code: HD-E808-60
Categories:
The Corrosion Resistance Testing Device is adapted for surface treatment of various materials after this anti-corrosion process, including painting, electroplating, organic and inorganic coatings, anodizing, rust preventive oil, etc., to test the corrosion resistance of products. It is suitable for parts, electronic components, metal materials, protective coatings, and industrial products.
Standard Parameters
| Model | HD-E808-60 |
| Internal Dimensions (W * D * H) | 600 * 450 * 400 mm |
| External Dimensions (W * D * H) | 1060 * 580 * 1050 mm |
| Chamber Material | P.V.C hard plastic sheet, thickness 8mm |
| Sample Trays | 10mm diameter fiberglass rod, rust-proof. V-shaped plastic steel to ensure samples are tilted at 15 ~ 30 degrees. |
| Temperature Range | Room temperature ~ 55 ℃ |
| Temperature Fluctuation | ≤ ± 0.5 ℃ |
| Temperature Uniformity | ≤ ± 2 ℃ |
| Temperature Accuracy | ± 1 ℃ |
| Spray Method | Continuous and Periodic spray type |
| Test Chamber Temperature | Spray Salt Test Method (NSS ACSS) 35 ± 1 ℃ Corrosion Resistance Test Method (CASS) 50 ± 1 ℃ |
| Saturated Air Tank Temperature | Spray Salt Test Method (NSS ACSS) 47 ± 1 ℃ Corrosion Resistance Test Method (CASS) 63 ± 1 ℃ |
| Salt Water Temperature | 35 ℃ ± 1 ℃ |
| Spray Amount | 1.0 ~ 2.0 ml / 80cm2 / hour |
| pH Value | Spray Salt Test Method (NSS ACSS6.5 ~ 7.2) Corrosion Resistance Test Method (CASS) 3.0 ~ 3.2 |
| Lab Volume | 108L |
| Salt Water Tank Capacity | 25L |
| Multiple Safety Protection Devices | Current discharge protection, overpressure protection, over-temperature protection, overload fuse protection |
| Accessories | Test Salt / Measuring tank / Nozzle Equipment x 1 set |
| Air Source | 1HP Air pump (provided by the buyer) |
Test Method
ASTM B117-08, ISO 9227...
And IEC, MIL, DIN, ASTM and other equivalent standards.
Product Features
- Durable hard 8mm PVC construction, corrosion-resistant and easy to clean.
- Reservoirs with mixing system on the stand.
- Separate the heating system from the salt test chamber to ensure accurate results and protect the circuit.
- Exposure area covered with corrosion-resistant PVC plates.
- Transparent cover allows viewing of test conditions.
- Peaked cover prevents condensation from dripping onto samples.
- Waterproof and water level protection system.
- Heated humidification tower with air relief valve, adjustable tower tip for directing salt spray.
- Automatically fills DI water into the humidification tower.
- Digital temperature control.
- Integrated over-protection on heaters.
- Low water cut-off protection in the humidification tower.