Determination of maximum service temperature, for preformed pipe insulation

Standard: EN 14707

The pipe-type insulation material is exposed to one-sided thermal treatment for a certain period after reaching its maximum service temperature at a specified rate of temperature increase. Following this process, thickness, length, and width measurements are taken.

While the thickness of the test sample is continuously measured during the thermal treatment, the length and width values are measured only after reaching ambient temperature, and the test results are obtained.

Standard Features

  • Easy and long-lasting use with 4.3" touch screen
  • Aluminum heating pipe
  • Ability to transfer time-based data logs to computer via USB
  • Temperature adjustment between ambient temperature and 200°C
  • 50 Pa pressure plate
  • 50°C/hour heating rate
  • 20 mm stroke compressor
  • 0.01 mm resolution
  • Fully automatic testing capability

Additional Features

  • Heating pipe options in desired diameters
  • Custom programming software option according to user requirements

Technical Specifications

  • Height: 110 cm
  • Width: 110 cm
  • Depth: 50 cm
  • Weight: 40 kg
  • Operating voltage: 220VAC - 1 KW